Fixed bug 4920 - Wider support for seconds of battery life left on Linux platforms using sys interface
Murad On my system, SDL_GetPowerInfo() returns -1 seconds of battery life left. I have quickly investigated that in my case SDL uses sys interface to get battery data. It tries to read "time_to_empty_now" file which is not always present. However, it is still possible to calculate remaining lifetime using "energy_now" and "power_now" files. This is what my simple patch (included as attachment) tries to accomplish. Best wishes.
This commit is contained in:
parent
8b0660b25a
commit
58a11d30de
|
@ -451,6 +451,8 @@ SDL_GetPowerInfo_Linux_sys_class_power_supply(SDL_PowerState *state, int *second
|
||||||
SDL_PowerState st;
|
SDL_PowerState st;
|
||||||
int secs;
|
int secs;
|
||||||
int pct;
|
int pct;
|
||||||
|
int energy;
|
||||||
|
int power;
|
||||||
|
|
||||||
if ((SDL_strcmp(name, ".") == 0) || (SDL_strcmp(name, "..") == 0)) {
|
if ((SDL_strcmp(name, ".") == 0) || (SDL_strcmp(name, "..") == 0)) {
|
||||||
continue; /* skip these, of course. */
|
continue; /* skip these, of course. */
|
||||||
|
@ -492,11 +494,16 @@ SDL_GetPowerInfo_Linux_sys_class_power_supply(SDL_PowerState *state, int *second
|
||||||
pct = (pct > 100) ? 100 : pct; /* clamp between 0%, 100% */
|
pct = (pct > 100) ? 100 : pct; /* clamp between 0%, 100% */
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!read_power_file(base, name, "time_to_empty_now", str, sizeof (str))) {
|
if (read_power_file(base, name, "time_to_empty_now", str, sizeof (str))) {
|
||||||
secs = -1;
|
|
||||||
} else {
|
|
||||||
secs = SDL_atoi(str);
|
secs = SDL_atoi(str);
|
||||||
secs = (secs <= 0) ? -1 : secs; /* 0 == unknown */
|
secs = (secs <= 0) ? -1 : secs; /* 0 == unknown */
|
||||||
|
} else if (st == SDL_POWERSTATE_ON_BATTERY) {
|
||||||
|
/* energy is Watt*hours and power is Watts */
|
||||||
|
energy = (read_power_file(base, name, "energy_now", str, sizeof (str))) ? SDL_atoi(str) : -1;
|
||||||
|
power = (read_power_file(base, name, "power_now", str, sizeof (str))) ? SDL_atoi(str) : -1;
|
||||||
|
secs = (energy >= 0 && power > 0) ? (3600LL * energy) / power : -1;
|
||||||
|
} else {
|
||||||
|
secs = -1;
|
||||||
}
|
}
|
||||||
|
|
||||||
/*
|
/*
|
||||||
|
|